Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
Biomimetics (Basel) ; 9(4)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38667205

RESUMO

Solvent evaporation within an adhesive layer is a crucial step during a bonding process. The aim of this current research was to test whether the use of different air temperatures (20 °C, 40 °C, and 60 °C) for solvent evaporation improves the performance of four adhesive systems to dentin. Sixty non-carious human molar teeth were randomly prepared for micro-tensile bond strength (µTBS) tests. Four different adhesive systems, Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE), were applied following the manufacturer's instructions. Three groups based on the air-drying temperature were used: solvent evaporation was performed with either of warm (40 °C), (60 °C), and cold air as control group (20 °C) for 10 s at a distance of 5 cm. In all bonded surfaces, three resin composite (Reflectys, Itena Clinical, Paris, France) layers of 2 mm thickness were built up. The resin-dentin samples were kept in distilled water at 37 °C for 24 h and 6 months, respectively, before µTBS testing. Failure analysis, scanning electron microscopy of resin-dentin bonded interface, and solvent evaporation rate were tested as secondary variables. All analyses were conducted using a significance level of α = 0.05. Bond strength (BS) values were similar among all the adhesive systems used (p > 0.05). Also, the aging factor did not affect the BS (p > 0.05). Only the factor of temperature used for solvent evaporation resulted in a statistically significant effect (p < 0.05), with the temperature of 60 °C being the highest value (p < 0.05). A failure mode evaluation revealed mostly adhesive or mixed modes of failures in all the different temperatures of air used for the solvent evaporation of each adhesive system. The thickness of the adhesive layer and the creation of resin tags varied amongst the temperatures evaluated. For all adhesive systems tested, the use of 40 °C or 60 °C air for solvent evaporation led to an increased mass loss. Warmer temperatures for solvent evaporation contributed positively to bonding performance, enhancing both the quality of the adhesive layer and its interaction with the dentin tissue. Optimizing solvent evaporation with warmer air temperatures (40 °C and 60 °C) significantly improved µTBS, offering a practical means to enhance the quality and longevity of adhesive restorations in esthetic dentistry.

2.
Dent J (Basel) ; 12(3)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38534272

RESUMO

BACKGROUND: Candida albicans and similar species are significant pathogens in immunocompromised and hospitalized individuals, known for mucosal colonization and bloodstream/organ invasion. Many pathogenic fungi, including these species, exhibit autofluorescence (R/OF) under specific light conditions, a feature crucial for their detection. AIM: We investigated the use of a 405 nm diode laser for the direct observation of red/orange autofluorescence of Candida spp., common in the oral cavity, exploring its potential in health screenings. METHODS: This study utilized cultures of Candida spp. on Sabouraud dextrose agar with Qdot 655 and 685 for fluorescence benchmarking, illuminated using a 405 nm diode laser (continuous wave, power 250 mW, 0.0425 J/cm² fluence, 0.0014 W/cm² power density). Images were captured using a yellow-filter camera at set intervals (48 to 144 h). Visual and computational analyses evaluated the R/OF in terms of presence, intensity, coloration, and intra-colony variation. RESULTS: Most Candida strains displayed red/orange autofluorescence at all observation times, characterized by varied coloration and intra-colony distribution. Initially, there was an increase in R/OF intensity, which then stabilized in the later stages of observation. CONCLUSIONS: The majority of the Candida strains tested are capable of emitting R/OF under 405 nm laser light. This finding opens up new possibilities for integrating R/OF detection into routine dental screenings for Candida spp.

3.
Nanomaterials (Basel) ; 14(3)2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38334546

RESUMO

This study aimed to assess the ability of modern resin-based "bioactive" materials (RBMs) to induce dentine remineralisation via mineral deposition and compare the results to those obtained with calcium silicate cements (CSMs). The following materials were employed for restoration of dentine cavities: CSMs: ProRoot MTA (Dentsply Sirona), MTA Angelus (Angelus), Biodentine (Septodont), and TheraCal LC (Bisco); RBMs: ACTIVA BioACTIVE Base/Liner (Pulpdent), ACTIVA Presto (Pulpdent), and Predicta Bioactive Bulk (Parkell). The evaluation of the mineral deposition was performed through scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) on the material and dentine surfaces, as well as at the dentine-material interface after immersion in simulated body fluid. Additionally, the Ca/P ratios were also calculated in all the tested groups. The specimens were analysed after setting (baseline) and at 24 h, 7, 14, and 28 days. ProRoot MTA, MTA Angelus, Biodentine, and TheraCal LC showed significant surface precipitation, which filled the gap between the material and the dentine. Conversely, the three RBMs showed only a slight ability to induce mineral precipitation, although none of them was able to remineralise the dentine-material interface. In conclusion, in terms of mineral precipitation, modern "bioactive" RBMs are not as effective as CSMs in inducing dentine remineralisation; these latter represent the only option to induce a possible reparative process at the dentin-material interface.

4.
Sci Rep ; 14(1): 4124, 2024 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-38374199

RESUMO

The aim of this study was to evaluate cytotoxicity and genotoxicity of calcium-silicate based sealers and comparing them with a gold standard-an epoxy-based sealant. Two experimental cell lines were used, gingival fibroblasts (hGF) and monocyte/macrophage peripheral blood cell line (SC). The cytotoxicity (XTT assay) and genotoxicity (comet assay) were evaluated both after 24-h and 48-h incubation. Additionally, after 48-h incubation, the cell apoptosis and cell cycle progression was detected. BioRoot Flow induced a significant decrease in hGF cells viability compared to the negative control groups both after 24-h (p < 0.001) and 48-h incubation (p < 0.01). In group with SC cells, after 24-h incubation significant increase in cells viability was detected for AH Plus Bioceramic Sealer in comparison to negative control (p < 0.05). BioRoot Flow and BioRoot RCS can be considered potentially genotoxic for the hGF cells after 48-h incubation (> 20% DNA damage). BioRoot Flow and BioRoot RCS, may have potential genotoxic effects and induce apoptosis in hGF cells which may irritate periapical tissues, resulting in a delayed healing. The findings of the study would be useful in selection of an appropriate sealant for root canal filling without causing cytotoxicity and genotoxicity.


Assuntos
Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/toxicidade , Cavidade Pulpar , Resinas Epóxi/toxicidade , Compostos de Cálcio , Linhagem Celular , Dano ao DNA , Resinas Vegetais , Silicatos/toxicidade , Teste de Materiais
5.
Clin Oral Investig ; 28(2): 132, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308668

RESUMO

OBJECTIVES: This study aimed at comparing the microtensile bond strength (MTBS) and interfacial adaptation of a modern self-curing and a light-curing restorative bulk-fill composite to a conventional composite applied with the layering technique. METHODS: Forty-eight occlusal cavities were divided in three main groups (16/group) based on tested materials: (i) STELA, bulk-fill self-curing restorative (STELA, SDI Ltd.); (ii) 3 M-BULK, bulk-fill composite (Filtek One Bulk-Fill, 3 M Oral Care); and (iii) 3 M-CTR, a conventional composite (Filtek Supreme XTE, 3 M Oral Care). These were used in combination with their adhesives in self-etch (SE) or etch-and-rinse (ER) mode. Specimens stored in artificial saliva (24 h or 12 months) were evaluated for MTBS and fractography. The interfacial analysis was performed through confocal microscopy. ANOVA and Fisher's LSD post hoc tests were performed with a level of significance of 5%. RESULTS: All the tested materials applied in ER mode presented (24 h) greater bond strength than in SE mode. Although all materials showed a significant drop in the bond strength after prolonged storage, STELA showed the highest bonding performance and interfaces with few gaps. 3 M-BULK had the lowest bond strength and an interface with several voids and gaps. CONCLUSIONS: All materials were affected by interface degradation and bonding reduction over prolonged aging. However, their use in combination with adhesives applied in ER mode may offer greater immediate bonding performance. CLINICAL RELEVANCE: The use of restorative light-curing bulk-fill composites may generate gaps at the bonding interface and voids. STELA may represent a suitable alternative to avoid such issues.


Assuntos
Colagem Dentária , Cimentos de Resina , Saliva Artificial , Cimentos de Resina/química , Resinas Compostas/química , Teste de Materiais
6.
Pol Arch Intern Med ; 134(4)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38226583

RESUMO

INTRODUCTION: Acute pulmonary embolism (APE) is the most serious manifestation of venous thromboembolism. The simplified Pulmonary Embolism Severity Index (sPESI) is employed for prediction of 30-day mortality in APE. The Vulnerable Elders Survey (VES-13) is used to identify participants at a risk of health impairment. OBJECTIVES: We aimed to compare the VES-13 and sPESI scales for prediction of 3-month mortality inelderly patients hospitalized for APE. PATIENTS AND METHODS: All patients with APE were managed according to the European Society of Cardiology (ESC) guidelines and followed up for at least 3 months after discharge. Clinical evaluation of all patients involved the Charlson Comorbidity Index (CCI) and biochemical tests. The patients with VES-13 score equal to or above 3 (VES-13≥3) were evaluated with comprehensive geriatric assessment (CGA). RESULTS: A total of 164 patients met the inclusion criteria. There were significantly fewer men in the VES-13≥3 than the VES-13<3 group (34% vs 54.5%; P <0.01). The patients in the VES-13≥3 group had lower median (interquartile range [IQR]) body mass index and higher sPESI score than those in the VES-13<3 group (25.6 [21.8-28.4] kg/m2 vs 28 [25.3-31] kg/m2; P = 0.001 and 2 [1-2] points vs 1 [0-1] point; P <0.001, respectively). There were no differences in APE severity according to the ESC stratification and CCI. Logistic regression analysis identified the VES-13 score as a significant independent risk factor for 3-month mortality. CONCLUSIONS: The VES-13 score is a better tool than sPESI for predicting 3-month mortality. Geriatric survivors of APE characterized with VES-13≥3 points should be closely monitored after discharge. The Norton Scale Score in a combination with the VES-13 may be useful in predicting 3-month mortality among numerous tests used in the CGA.


Assuntos
Avaliação Geriátrica , Embolia Pulmonar , Humanos , Masculino , Idoso , Feminino , Embolia Pulmonar/mortalidade , Embolia Pulmonar/diagnóstico , Idoso de 80 Anos ou mais , Avaliação Geriátrica/métodos , Índice de Gravidade de Doença , Sobreviventes , Alta do Paciente
7.
Heliyon ; 10(1): e23708, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38205295

RESUMO

Objectives: Bruxism is a repetitive activity of the masticatory muscles characterized by clenching or grinding teeth and/or mandibular stiffening. Bruxism manifests itself in two forms: during sleeping and waking. The etiology of bruxism is multifactorial. The treatment of bruxism is mainly based on making the patient aware of the presence of the condition. The aim of the study was to assess knowledge on the causes and the effects of bruxism among Polish students as well as the possible management. Materials and methods: The anonymous online survey was conducted among students (aged between 18 and 25 years old) of universities across Poland, using the Google Forms platform. The survey contained questions concerning bruxism causes, effects and therapies. All variants of answers in these questions contained true information about bruxism. Results: The study found significant differences in awareness of bruxism among genders in favor of females. The awareness of bruxism among population residing in cities and in villages was comparable (p > 0.05). However, the results should be taken with care due to limited number of students that participated in the study and uneven gender distribution among urban and village residents. Conclusions: Within the limitations of the study it can be concluded that the knowledge of bruxism among Polish students is higher in comparison with the findings from the literature, as well as the superiority of women's awareness of bruxism over men. Future studies should be conducted on greater student population, with even distribution of participants among country areas and variety of universities. Significance: The findings may indicate the need for further education of male young adults, on bruxism causes, possible effects and therapies to increase their awareness of bruxism and encourage early diagnosis and treatment.

8.
Materials (Basel) ; 16(22)2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38005131

RESUMO

The increasing demand for orthodontic treatments due to the high prevalence of malocclusion has inspired clinicians and material scientists to investigate innovative, more effective, and precise bonding methods with reduced chairside time. This study aimed at comparing the shear bond strength (SBS) of metal and ceramic brackets bonded to enamel using the indirect bonding technique (IDB). Victory Series metal brackets (Metal-OPC, Metal-APC) and Clarity™ Advanced ceramic brackets (Ceramic-OPC) (3M Unitek, Monrovia, CA, USA) were bonded indirectly to extracted human premolars through the etch-and-rinse technique. A qualitative assessment of the enamel surface using microscopic methods was performed, and the amount of residual adhesive was reported as per the adhesive remnant index (ARI). Moreover, the bracket surface was evaluated with SEM-EDS. The highest SBS mean values were observed in the Ceramic-OPC group (16.33 ± 2.01 MPa), while the lowest ones were obtained with the Metal-OPC group (11.51 ± 1.40 MPa). The differences between the Metal-AOPC vs. Metal-APC groups (p = 0.0002) and the Metal-OPC vs. Ceramic-OPC groups (p = 0.0000) were statistically significant. Although the Ceramic-OPC brackets bonded indirectly to the enamel surface achieved the highest SBS, the enamel damage was significantly higher compared to that of the other groups. Thus, considering the relatively high bond SBS and favourable debonding pattern, Metal-APC brackets bonded indirectly may represent the best choice.

9.
Materials (Basel) ; 16(20)2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37895605

RESUMO

Metals subjected to the oral environment are prone to corrosion over time and this can be harmful. Metallic restoration components such as dental subgingival implant abutments are exposed to pH changes and different ions while in contact with saliva. The aim of the study was to evaluate the corrosion resistance of titanium dental implant abutments and to compare and contrast the surface characteristics of these alloys before and after corrosion. The corrosion examination (Ecorr, jcorr, OCP, polarization curve) of two implant abutments (TiDesign EV, Astra Tech, Dentsply, York, PA, USA; Individual Titanium Abutment, Apollo Implants Components, Pabianice, Poland) was performed in 0.9% NaCl and 5% HCl. Moreover, specimens were investigated using SEM-EDS before and after the corrosion test. The value of jcorr in NaCl was higher for Astra (34.2 × 10-8 ± 2.5 × 10-8 A/cm2) than for Apollo (8.8 × 10-8 ± 2.5 × 10-8 A/cm2). Whereas, in HCl, the opposite relationship was observed (Astra 2.9 × 10-4 ± 0.8 × 10-4 A/cm2 and Apollo 62.7 × 10-4 ± 9.3 × 10-4 A/cm2). An average reactive anodic current density in NaCl for Astra amounted up to ~0.2 × 10-5-1.5 × 10-5 A/cm2, while for Apollo-up to ~3.3-9.7 × 10-7 A/cm2. The composition of both alloys after corrosion in NaCl demonstrated some changes: a decrease in the Ti, and Al and an increase in oxygen content. Hence, both alloys after corrosion in HCl demonstrated some minor changes in the elemental composition. Based on the results it can be concluded that: 1. Astra and Apollo abutments revealed good corrosion resistance and a passivation layer on the surface. 2. Apollo abutments exhibited better corrosion resistance in a neutral environment, suggesting that Astra abutments were found to be more resistant to corrosion in an acidic medium.

10.
Materials (Basel) ; 16(20)2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37895679

RESUMO

Successful orthodontic therapy, apart from a proper treatment plan, depends on optimal bracket-enamel adhesion. Among numerous factors affecting adhesion, the type of bracket and preparation of the tooth's surface are crucial. The aim of this study was to compare the shear bond strength (SBS) of metal and ceramic brackets to the enamel's surface using direct bonding. Forty extracted human premolars were divided into four groups according to the etching method (etch-and-rinse and self-etch) and bracket type. The SBS and adhesive remnant index (ARI) were determined. The ceramic brackets achieved the highest SBS values both in the self-etch (SE) and etch-and-rinse (ER) protocols. Higher SBS values for ceramic and metallic brackets were found in the ER protocol. In all tested groups, the achieved SBS value was satisfactory to withstand orthodontic and occlusal forces. There was no significant difference in the ARI score between study groups (p = 0.71). The fracture occurred between the bracket base and adhesive material in both types of brackets, which decreased the risk of enamel damage during debonding.

11.
J Funct Biomater ; 14(10)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37888187

RESUMO

The goal of this article was to assess the effect of modified triple-layer application (MTLA) in conjunction with the active bonding technique on the bond strength of four adhesive systems to dentinal substrate. The adhesives tested were Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE). The adhesives were applied according to the following strategies: single active application (A) and triple adhesive layer application including Active-Passive-Passive (APP); AAP; and AAA. The micro-tensile bond strength test was evaluated following 24 h or 6 months of storage. The composite-dentin interface morphology was investigated using scanning electron microscopy. The data were statistically analyzed with a significance level of α = 0.05. At 24 h of aging, all of the factors tested were not significant (p > 0.05) for CSE. For OBFL, OBU, and PBU, statistically higher values were observed for the A technique (p < 0.05). Plus, there were no significant variances between the APP, AAP, and AAA techniques (p > 0.05) for OBFL and PBU. However, for OBU, there were no significant differences between the A and AAA techniques (p > 0.05). After 6 months of aging, the A technique showed statistically higher values when compared to the other techniques (p < 0.01), except for OBFL, where the A and AAA techniques showed promising outcomes. When comparing the bond strength values of 24 h and 6 months, only for PBU, all of the techniques used resulted in bond strength stability over time (p > 0.05). Thicker adhesive layers were observed when MTLA was applied. Only the OBFL adhesive showed the formation of resin tags in all of the modalities tested. The bonding performances of the different application techniques used were material-dependent.

12.
J Prosthodont ; 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37653684

RESUMO

PURPOSE: This systematic review and meta-analysis aimed to evaluate the difference in the color stability of light-cured and dual-cured resin cements. MATERIALS AND METHODS: Two separate reviewers used the PubMed, Scopus, Web of Science, Embase, and Scielo databases to execute the systematic review. For the analysis, studies that evaluated the color stability of dual-cured and light-cured resin cements over time were used. The random effects model was used in the meta-analysis. Analyses of subgroups were carried out based on the aging technique. The methodological quality of each in vitro study was evaluated in accordance with the parameters of a prior systematic review. RESULTS: From all databases, a total of 2223 articles were retrieved. Following the screening of titles and abstracts, 44 studies were selected for full text review, and a total of 27 articles were used for the qualitative analysis. Finally, 23 articles remained for the qualitative analysis. The majority of studies were labeled as having a medium risk of bias. The global analysis showed that the dual-cure resin cements had considerably greater differences in the color change (p = 0.006). A high heterogeneity index (86%) was found in the analysis. CONCLUSIONS: The best available in vitro evidence suggests that dual-polymerizing cement has higher color variation than light-polymerized materials. To reduce the likelihood of color change after the luting of thin ceramic restorations, clinicians should employ light-polymerizable resin cements.

13.
J Esthet Restor Dent ; 35(8): 1218-1238, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37395344

RESUMO

INTRODUCTION: In a suitable condition, it is important to perform any dental restorative procedure using an operatory field isolated. Then, the aim of this study was to compare the bond strength of composite restorations to dentin affected by any contamination agent through a systematic review. METHODS: This systematic review was performed following the PRISMA 2020 guidelines. The literature search was conducted until September 2022 by scanning the following databases: Embase, PubMed, Scielo, Scopus, and Web of Science. Manuscripts evaluated the bond strength of resin-based materials to permanent human dentin contaminated with blood or saliva were selected for full-text review. The risk of bias was assessed by the RoBDEMAT tool. RESULTS: A total of 3750 papers resulted from the search from all databases. After the full-text reading, a total of 62 articles remained for the qualitative analysis. The contamination agents used were blood, saliva, and hemostatic agents. A great variety of protocols were used to contaminate the dentin surface, and the contamination process occurred in several steps of the bonding process, including before and after the etching process, after the primer application and after the adhesive application. Also, several decontamination procedures were tested, including reapplication of the etching material, rinsing with water, chlorhexidine or sodium hypochlorite and reapplication of the adhesive system. CONCLUSION: Any contamination with blood or saliva impaired the bond strength of resin-based materials to dentin. Decontamination procedures including water-spray and reapplication of the bonding system could revert the impairment produced by the saliva or blood contamination. The use of hemostatic agents as a method of blood decontamination is not recommended. CLINICAL SIGNIFICANCE: Clinicians should avoid contamination during a bonding procedure, otherwise, a reduction in the bond quality is expected.


Assuntos
Colagem Dentária , Hemostáticos , Humanos , Cimentos Dentários/química , Adesivos Dentinários/química , Cimentos de Resina/química , Resinas Compostas/química , Colagem Dentária/métodos , Propriedades de Superfície , Descontaminação , Hemostáticos/química , Dentina , Água/química , Teste de Materiais
14.
Materials (Basel) ; 16(12)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37374674

RESUMO

The assessment of microgaps at the implant-abutment interface is an important factor that may influence clinical success. Thus, the aim of this study was to evaluate the size of microgaps between prefabricated and customised abutments (Astra Tech, Dentsply, York, PA, USA; Apollo Implants Components, Pabianice, Poland) mounted on a standard implant. The measurement of the microgap was performed using micro-computed tomography (MCT). Due to 15-degree rotation of samples, 24 microsections were obtained. Scans were performed at four levels established at the interface between the abutment and the implant neck. Moreover, the volume of the microgap was evaluated. The size of the microgap at all measured levels varied from 0.1 to 3.7 µm for Astra and from 0.1 to 4.9 µm for Apollo (p > 0.05). Moreover, 90% of the Astra specimens and 70% of the Apollo specimens did not exhibit any microgaps. The highest mean values of microgap size for both groups were detected at the lowest portion of the abutment (p > 0.05). Additionally, the average microgap volume was greater for Apollo than for Astra (p > 0.05). It can be concluded that most samples did not exhibit any microgaps. Furthermore, the linear and volumetric dimensions of microgaps observed at the interface between Apollo or Astra abutments and Astra implants were comparable. Additionally, all tested components presented microgaps (if any) that were clinically acceptable. However, the microgap size of the Apollo abutment was higher and more variable than that of the Astra one.

15.
Materials (Basel) ; 16(11)2023 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-37297323

RESUMO

The use of materials for computer-aided design/computer-aided manufacturing (CAD/CAM) has been rapidly increasing in daily practice. However, one of the main issues regarding modern CAD/CAM materials is their aging in the oral environment, which may lead to significant changes in their overall properties. The aim of this study was to compare the flexural strength, water sorption, cross-link density (softening ratio%), surface roughness, and SEM analysis of three modern CAD/CAM "multicolor" composites. Grandio (Grandio disc multicolor-VOCO GmbH, Cuxhaven, Germany), Shofu (Shofu Block HC-Shofu Inc., Kyoto, Japan), and Vita (Vita Enamic multiColor-Vita Zahnfabrik, Bad Sackingen, Germany) were tested in this study. They were prepared in stick-shaped specimens and submitted to different tests after several aging protocols, such as thermocycling and mechanical cycle loading challenge. Further disc-shaped specimens were also created and tested for water sorption, cross-link density, surface roughness, and SEM ultramorphology, before and after storage in an ethanol-based solution. For flexural strength and ultimate tensile strength, Grandio showed the greatest values both at baseline and after aging (p < 0.05). Grandio and Vita Enamic presented the highest modulus of elasticity and the lowest water sorption (p < 0.05). A significant reduction (p < 0.05) in microhardness after ethanol storage (softening ratio%) was observed especially in Shofu. Grandio had the lowest roughness parameters compared to the other tested CAD/CAM materials, while ethanol storage significantly increased the Ra and RSm values in Shofu (p < 0.05). Despite the comparable modulus of elasticity of Vita and Grandio, this latter showed greater flexural strength and ultimate tensile strength both at baseline and after aging. Hence, Grandio and Vita Enamic may be employed for the anterior teeth and for those restorations requiring load-bearing capacity. Conversely, aging seems to affect several properties of Shofu, so its use for permanent restorations should be well-pondered based on the clinical situation.

16.
J Clin Med ; 12(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36902775

RESUMO

The etiology of temporomandibular disorders (TMDs) is firmly anchored in the biopsychosocial model in which a special role is attributed to the stress, depression, somatic symptoms, and anxiety. The aim of the study was to assess the level of stress, depression and neck disability in patients with temporomandibular disorder-myofascial pain with referral. The study group enrolled 50 people (37 women and 13 men) with complete natural dentition. All the patients underwent a clinical examination according to the Diagnostic Criteria for Temporomandibular Disorders and were diagnosed as individuals with myofascial pain with referral. The questionnaires were associated with stress, depression, and neck disability; Perceived Stress Scale (PSS-10), Beck Depression Inventory(BDI), and Neck Disability Index (NDI) were evaluated. Of the individuals evaluated, 78% showed elevated levels of stress, and the average value of the PSS-10 in the study group was 18 points (Me = 17). Furthermore, 30% of the subjects presented depressive symptoms, with the average value of BDI was 8.94 points (Me = 8), and 82% of the subjects showed neck disability. The multiple linear regression model revealed that BDI and NDI allowed explanations for the 53% differentiation of PSS-10. In conclusion, stress, depression, and neck disability coexist with temporomandibular disorder-myofascial pain with referral.

17.
Bioengineering (Basel) ; 10(2)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36829663

RESUMO

Nowadays, the ceramic veneer approach can be considered more predictable than direct composite veneer. To date, there is a lack of studies comparing the clinical performance of anterior veneers cemented on vital teeth (VT) and non-vital teeth (NVT). This longitudinal clinical study investigated the performance of ceramic veneers in VT or anterior NVT. A total of 55 patients were evaluated in the study. Two groups were defined based on the vitality status of the teeth (93 teeth-vital and 61 teeth-non-vital). The United States Public Health Service (USPHS) criteria were used to assess the clinical status. The data were evaluated statistically with the Mann-Whitney U test. All restorations were considered acceptable, and only one veneer in VT failed for the criteria of secondary caries. There were no statistically significant differences in any of the criteria evaluated (p ≤ 0.671). The ceramic veneers evaluated showed a satisfactory clinical performance both in VT and NVT.

18.
Bioengineering (Basel) ; 10(2)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36829708

RESUMO

Currently, it remains unclear which specific peptides could be appropriate for applications in different fields of dentistry. The aim of this scoping review was to scan the contemporary scientific papers related to the types, uses and applications of peptides in dentistry at the moment. Literature database searches were performed in the following databases: PubMed/MEDLINE, Scopus, Web of Science, Embase, and Scielo. A total of 133 articles involving the use of peptides in dentistry-related applications were included. The studies involved experimental designs in animals, microorganisms, or cells; clinical trials were also identified within this review. Most of the applications of peptides included caries management, implant osseointegration, guided tissue regeneration, vital pulp therapy, antimicrobial activity, enamel remineralization, periodontal therapy, the surface modification of tooth implants, and the modification of other restorative materials such as dental adhesives and denture base resins. The in vitro and in vivo studies included in this review suggested that peptides may have beneficial effects for treating early carious lesions, promoting cell adhesion, enhancing the adhesion strength of dental implants, and in tissue engineering as healthy promotors of the periodontium and antimicrobial agents. The lack of clinical trials should be highlighted, leaving a wide space available for the investigation of peptides in dentistry.

19.
Cells ; 12(1)2023 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-36611983

RESUMO

Diverse types of dental adhesives exhibit different cytotoxic outcomes on cells in vitro. Currently, no standard adhesive application technique has so far been decisive for clinicians for better durability of resin-dentin bonds of adhesive systems. The purpose of this study was to systematically review the literature to evaluate the bonding performance of adhesive systems to dentin by using different application modalities. The systematic research strategy was conducted by two reviewers among multiple databases: PubMed, Scopus, Web of Science, Embase, and Scielo. In vitro studies reporting the effects of additional steps for the application of adhesive systems on the bond strength to dentin were selected. Meta-analysis was performed using Review Manager Software version 5.3.5 using the random effects model. The methodological quality of each in vitro study was assessed according to the parameters of a previous systematic review. The electronic research through different databases generated a total of 8318 references. After the examination of titles and abstracts, a total of 106 potentially relevant studies accessed the full-text evaluation phase. After full-text examination, 78 publications were included for the qualitative analysis, and 68 studies were included in the meta-analysis. Regarding the etch-and-rinse adhesive systems, the application modalities that improved the overall bond strength were the application of a hydrophobic resin layer (p = 0.005), an extended application time (p < 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p = 0.05), the agitation technique (p = 0.02), and the active application of the adhesive (p < 0.001). For self-etch adhesive systems, the techniques that improved the overall bond strength were the application of a hydrophobic resin layer (p < 0.001), an extended application time (p = 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p < 0.001), the agitation technique (p = 0.01), and the active application of the adhesive (p < 0.001). The in vitro evidence suggests that the application of adhesive systems using alternative techniques or additional strategies may be beneficial for improving their bond strength to dentin. The application modalities that favored the overall bond strength to dentin were an extended application time, a double-layer application, an application assisted by an electric current, the active application of the adhesive, and the application of a hydrophobic resin layer. Worth mentioning is that some techniques are intended to increase the degree of the conversion of the materials, and therefore, improvements in the biocompatibility of the materials can be expected.


Assuntos
Adesivos , Dentina , Adesivos Dentinários/química , Teste de Materiais , Cimentos de Resina/química
20.
J Esthet Restor Dent ; 35(3): 493-500, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36260931

RESUMO

OBJECTIVE: Problems in the confection of indirect restorations may increase the marginal and internal gap. This study aimed to quantify the marginal and the internal fit of overlays fabricated with three different materials. MATERIALS AND METHODS: Standardized cavities were prepared on endodontically treated human third molars and digital impressions were done using an intraoral camera (Trios 3). Restorations were designed (n = 15) and fabricated with three materials: Hybrid ceramic (Cerasmart; GC Corp, EUROPE), high-strength lithium disilicate (GC Initial® LiSi Press; GC Corp, Tokyo, Japan), and zirconia reinforced Lithium Silicate Glass Ceramic (Vita Suprinity; Vita, Germany). Axial, marginal, pulpal, and gingival gaps were calculated by measuring the distance between the restoration and the tooth at several reference points. Two-Way analysis of variance was used for statistical analysis. The significance level was set at α = 0.05. RESULTS: Mean gap was significantly influenced by the material (p < 0.001), gap localization (p < 0.001), and interaction between the factors (p = 0.002). For all materials, the highest gap was observed at gingival and pulpal surfaces (p ≤ 0.015). LiSi Press achieved the overall lowest values at axial values measurements (p ≤ 0.003). CONCLUSIONS: The performance of a CAD/CAM system relative to marginal adaptation is influenced by the restorative material used. High-strength lithium disilicate seems to be showed the best marginal adaptation. CLINICAL SIGNIFICANCE: Marginal and internal adaptation of CAD/CAM restorations could be influenced by the type of material chosen.


Assuntos
Coroas , Planejamento de Prótese Dentária , Humanos , Adaptação Marginal Dentária , Materiais Dentários , Desenho Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...